Reznor R6GF Unit Installation Manual Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Radiátory Reznor R6GF Unit Installation Manual. Reznor R6GF Unit Installation Manual User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 36
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
ATTENTION INSTALLERS:
It is your responsibility to know this product better than your customer. This includes being able to install the product according
to strict safety guidelines and instructing the customer on how to operate and maintain the equipment for the life of the product.
Safety should always be the deciding factor when installing this product and using common sense plays an important role as
well. Pay attention to all safety warnings and any other special notes highlighted in the manual. Improper installation of the unit
or failure to follow safety warnings could result in serious injury, death, or property damage. These instructions are primarily
intended to assist qualified individuals experienced in the proper installation of this appliance. Some local codes require
licensed installation/service personnel for this type of equipment. After completing the installation, return these instructions to
the customer’s package for future reference.
15 SEER / 80% AFUE
Single Package Gas Heating / Electric Cooling
R6GF / PPG2GF - REV. A SERIES
Premium Model Shown
INSTALLATION INSTRUCTIONS
DO NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
WHAT TO DO IF YOU SMELL GAS
• Donottrytolightanyappliance.
• Donottouchanyelectricalswitch;donot
useanyphoneinyourbuilding.
• Leavethebuildingimmediately.
• Immediatelycall yourgas supplier froma
neighborsphone.Followthegassuppliers
instructions.
• Ifyoucannotreachyourgassupplier,call
theredepartment.
WARNING:
FIRE OR EXPLOSION HAZARD
•Failure to follow safety warnings exactly
could result in serious injury or property
damage.
•Installationandservicemustbeperformed
byaqualiedinstaller,serviceagencyorthe
gassupplier.
• Do not store or use gasoline or other
ammablevaporsandliquidsinthevicinity
ofthisoranyotherappliance.
Zobrazit stránku 0
1 2 3 4 5 6 ... 35 36

Shrnutí obsahu

Strany 1 - WARNING:

ATTENTION INSTALLERS:It is your responsibility to know this product better than your customer. This includes being able to install the product accordi

Strany 2 - TAbLE OF CONTENTS

10• Electrical connections must be in compliance withall applicable local codes and ordinances, and with the current revision of the National

Strany 3

11√ Verify factory wiring is in accordance with the unit wiring diagram (Figures 12 & 13, pages 29 - 30). Verify the connections didn’t loosen du

Strany 4

12Checking Heat Anticipator Settings• Addthecurrentdrawofthesystemcomponents.OR• Measure the current ow on the thermostat R-W circuit

Strany 5 - Heating Load

13due to safety controls, defrost boards, or other control boards which could lead to nuisance alerts.Thermostat Demand WiringThe Comfort Alert module

Strany 6

14the compressor and will not operate properly if 24VAC is applied to the compressor solenoid terminals.To reduce the VA load of the solenoid on the s

Strany 7

15• Allgaspipingmustbeinstalledincompliancewithlocalcodesandutilityregulations.Intheabsenceoflocalcodesthegaslineinstallation

Strany 8

16After the gas piping to the unit is complete, all connections must be tested for gas leaks. This includes pipe connections at the main gas valve, em

Strany 9

17Table 6 (page 19) lists the correct orifice size to use at different altitudes.After changing the orifices, it is required that you measure the gas in

Strany 10 - AVERTISSEMENT:

18supply air side must be shielded against direct radiation from the heat exchanger to avoid false readings.2. Adjust all registers and duct dampers t

Strany 11 - Heat / Cool Thermostat

19RefrigerantCharging WARNING:These units are shipped fully charged withR-410Arefrigerantandreadyforinstallation.Whenasystemisinstal

Strany 12 - CAUTION:

2IMPORTANT SAFETY INFORMATION ...3REQUIREMENTS & CODES ...4GENERAL INFORMATION ...

Strany 13

20the inducer has been off for 60 minutes, the control energizes the inducer motor and restarts the 60 second pressure switch proving period.5. Pre-Pu

Strany 14

21skills, contact your dealer for maintenance. Consult your local dealer about the availability of maintenance contracts. Routinemaintenanceshouldi

Strany 15

222. Turn off all power to the unit and set the thermostat to the lowest temperature setting.3. Remove the louvered access panel from the unit.4. Turn

Strany 16

23COMPONENT FUNCTIONSComfort Alert™ Diagnostics -The Comfort Alert diagnostics module troubleshoots heat pump and air conditioning system failures and

Strany 17

24TopViewSide Viewback View24 9/1013 1/2161213 3/1013 1/21612CGA47 1/23/4" NPT FemaleDrain ConnectorBDOWNFLOWSUPPLY DUCTOPENINGDOWNFLOWRETURN DU

Strany 18

25AIRFLOW INFORMATIONTable11.AirowSettings(CFM)&Rise(°F)forHeatingOperationModeTable10.AirowSettingsforCoolingTable9.Nominal

Strany 19

26GAS INFORMATIONTable13.GasFlowRatesGAS FLOW RATESTIME FORONE REVOLUTION(SECONDS)CUbIC FEET PERREVOLUTION OF GAS METER1 5 1010 360 1,800 3,60012

Strany 20 - Fan Mode

27Figure10.GasValveLabelA. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do

Strany 21

28ELECTRICAL INFORMATIONFigure 11A. Two Stage Heating / Two Stage Cooling ConfigurationLegendField WiringFactory Wiring:TERMINAL STRIPTHERMOSTATRY1GY2C

Strany 22 - CAUTION:

29Figure12.TwoStageCool,TwoStageHeatCCHIFEQUIPPED987654321987654321987654321987654321240V208V 24VCOM123123HILOPRIMARYGAS VALVECL W2Y2R CY1 G W

Strany 23 - TROUbLESHOOTING

3IMPORTANT SAFETY INFORMATIONPlease read all instructions before servicing this equipment. Pay attention to all safety warnings and any other special

Strany 24 - FIGURES & TAbLES

30CCHIFEQUIPPED987654321987654321987654321987654321240V208V 24VCOM123123L W2Y2R CY1 G W15432154321VARIABLESPEEDBLOWERMOTOR123456789101112131415161234

Strany 25 - AIRFLOW INFORMATION

31Status LED StatusLEDDescription StatusLEDTroubleshootingInformationPOWER(Green LED)Module has power Supply voltage is present at module termina

Strany 26 - GAS INFORMATION

32Status LED StatusLEDDescription StatusLEDTroubleshootingInformationALERTFlash Code 3(Yellow LED)Short Cycling / Compressor is running only bri

Strany 27 - Figure10.GasValveLabel

33Table15.ModuleWiringTroubleshootingMiswired Module Indication RecommendedTroubleshootingActionGreen LED is not on, module does not power up•

Strany 28 - ELECTRICAL INFORMATION

34Liquid Pressure (psig)Liquid Temperature (° F)R6GF-X24 Charging Chart - Cooling20022024026028030032034036038040042044046048050052054056058060075 80

Strany 29 - WIRING DIAGRAM

35CHARGING CHARTS - CONTINUEDLiquid Pressure (psig)Liquid Temperature (° F)R6GF-X48 Charging Chart - Cooling200220240260280300320340360380400420440460

Strany 30

INSTALLATION / PERFORMANCE CHECK LISTGAS SYSTEMGasType:(circleone)Natural GasPropaneGas pipe connections leak-tested? YES NOGasLinePressure: ____

Strany 31

4metal edges present in all sheet metal constructed equipment.• Followall precautions inthe literature,on tags, andon labels provided with t

Strany 32

5GENERAL INFORMATIONThese Single Package Gas Heating / Electric Cooling Units are designed only for outdoor rooftop or ground level installations and

Strany 33 - REFRIGERANT CHARGING CHARTS

6 WARNING:CARbON MONOXIDE POISONING HAZARDFailure to follow the steps outlined below foreachapplianceconnectedtotheventingsystembeingp

Strany 34 - CHARGING CHARTS - CONTINUED

7Vent TerminationThis unit has been equipped with an integral venting system and designed to operate only with this venting system. No additional vent

Strany 35

8CIRCULATING AIR SUPPLY WARNING:Donotallowcombustionproductstoenterthereturnairductworkorthecirculatingairsupply.Failuretopreventth

Strany 36 - VENTING SYSTEM

9• Ifusingbottomdischargewithreturnairductsaroofcurb must be installed prior to unit installation. See Rigging and Hoisting section for set

Komentáře k této Příručce