Installation, Operation, and Parts for Power Venter,
Options CA1, CA2, CA3, and CA4
Form I-X Venter (Version A)
Obsoletes Form I-X/XE Venter
Applies to: Model X Duct Furnace plus
Obsolete Models (H)CX, DX,
(H)XE, (H)CXE, (C)XL, and (C)XLB
WARNING
Improper installation, adjustment, alteration, service, or maintenance can cause property
damage, injury or death. Read the installation, operation, and maintenance instructions
thoroughly before installing or servicing this equipment.
Description/
Application
WARNING
Optional power venter and venter ue adapter are designed for
USE WITH THESE DESIGNATED REZNOR
®
PRODUCTS ONLY.
•
DO NOT install these power venters on any other Reznor
®
equipment
including Reznor
®
Model F and Model B gravity-vented unit heaters. Use only
the power venting kits that are especially designed for F and B Models.
• DO NOT install these venters on equipment not manufactured with the
Reznor
®
brand.
*Models with prex "H" are not listed separately throughout this form. Information for corresponding
"standard" model applies to the "H" model.
** Power venter cannot be installed on XLB/CXLB Sizes 30-105 when equipped with an optional blower
cabinet.
The Option CA power venter is a motorized vent exhauster designed to permit the
installation of a gravity-vented heater in an area of negative pressure up to 0.15" w.c.
or where horizontal venting is required. The venter assembly in this instruction form is
designed for and may only be installed on the Reznor equipment listed below.
Use with Reznor
®
Models Description
X/DX/HX*; CX/HCX* Duct Furnace
XE/HXE*; CXE/HCXE* Packaged Duct Furnace & Blower
XL/CXL; XLB/CXLB** Fan & Blower Type Unit Heaters
HAZARD INTENSITY
LEVELS used in these
instructions
Components
Option packages are listed for currently manufactured Model X duct furnaces. Obso-
leted models are also listed where applicable. Review carefully and verify that the parts
are correct for the heater being serviced.
Packages Apply to Models X/DX
1
/CX
2
/XE/CXE
2
75 100 125 150-175 200-225 250-300
1
350
2
-400
Package P/N's by Option
CA Designation and
Voltage for Models
X/DX/CX/XE/CXE
Option CA1-115V 136959 136960 136961 136962 136963 136964 136965
Option CA2-208V 136966 136967 136968 136969 136970 136971 136972
Option CA3-230V 136973 136974 136975 136976 136977 136978 136979
Option CA4-460V 136980 136981 136982 136983 136984 136985 136986
Components In Option(s) Component P/N's
Venter Sub Assembly
CA1 29992 29994
CA2 30229 30233
CA3 30231 30235
CA4 29992 29994
Transformer .25KVA CA4 only 11279 (460 to 115)
Venter Flue Adapter All (CA1,2,3,4) 14516 6536 6539 6542 12730 12731 12732
2
1
For Model DX300, select package for Model X400.
2
Package P/N's listed do not apply to Model CX350 or Model CXE350. These
models require the same components as listed for a Size 350 except the venter ue adapter is different. Venter Flue Adapter
required is P/N 46163.